| Rated Pressure Range |
0.0 ~ -101.3kPa |
|
Operating / Setting Pressure Range |
10.0 ~
-101.3kPa |
| Withstand Pressure |
3 Times of Rated Pressure Range |
|
Fluid |
Air,
Non-Corrosive Gases, Incombustible Gases |
|
Set Pressure
Resolution |
kPa |
0.1 |
| MPa |
- |
| kgf/cm² |
0.001 |
| bar |
0.001 |
| psi |
0.01 |
| In. Hg |
0.1 |
| mm Hg |
1 |
| mm H20 |
0.1 |
| Power Supply Voltage |
12 to 24 VDC ±10% Ripple (P - P)
10% or less |
|
Current Consumption |
≤ 55mA |
| Switch Output |
PNP open collector 2 outputs
Max. load current: 80mA
Max. supply voltage: 30VDC
Residual voltage: ≤ 1V (load current 80mA) |
|
Repeatability (Switch Output) |
≤ ±0.2% F.S.
±1 1igit |
| Hysterisis |
Hysterisis Mode |
Adjustable |
| Window
Comparator Mode |
Fixed (3
digits) |
| Response Time |
≤ 2.5 ms (chattering-proof
function: 24 ms, 192 ms and 768 ms selections) |
|
Output Short Circuit Protection |
Yes |
| 7 Segment LED
Display |
3½ digit LED 7 segment display
(Sampling rate: 5 times/1 sec.) |
|
Indicator Accuracy |
≤ 2% F.S. ± 1
digit (ambient temp.: 25 ±3° C) |
| Indicator |
Green LED (Out 1) Red LED (Out
2) |
|
Environment |
Enclosure |
IP40 |
| Ambient Temp.
Range |
Operation:
0~50° C, Storage: 20~60% RH (No condensation or freezing) |
| Ambient
Humidity Range |
Operation/Storage: 35~85% RH (No condensation) |
| Withstand
Voltage |
1000VAC in
1-min (between case and lead wire) |
| Insulation
Resistance |
50Mohm min.
(at 500VDC M, between case and lead wire) |
| Vibration |
Total
amplitude 1.5mm, 10Hz-55Hz-10Hz scan for 1 minute, two hours each direction
of X, Y and Z |
| Shock |
980m/s²
(100G), 3 times each in direction of X, Y and Z |
|
Temperature characteristic |
≤ ±2% F.S. of
detected pressure (25° C) at temp. Range of 0~50° C |
|
Port Size |
F1:1/8"NPT,
M5; F2: 1/8"NPT, M5; F3: G1/8", M5 |
|
Lead Wire |
Oil-resistance
cable (0.15mm²) |
|
Weight |
Approx. 67g
(with 2-meter wire) Approx. 35 g (with male connector) |